Why balconies fail
- No membrane at all. Very common — tiles laid straight onto a screed, with the tile joints treated as the waterproofing.
- Falls running the wrong way. Toward the building instead of away from it, so water sits against the threshold.
- No drip edge. Water wraps back under the slab edge and tracks into the wall below.
- Rigid coating on a moving slab. The membrane cracks at exactly the points that move most.
- Blocked or absent outlet. A balcony with no scupper becomes a shallow pond in a Cape winter.
- Failed junction at the door threshold. The single most common entry point on any balcony.
The system we use
A polyurethane membrane, reinforced at the movement joints and dressed up all abutments and into the outlet, over a screed corrected to fall away from the building. Then either a tile on a drainage mat, or a trafficable top-coat where the finish level cannot be raised.
PU is specified over acrylic here because it keeps its elongation — a balcony slab moves seasonally, and a coating that cannot stretch will split along the line of that movement.
Sectional-title balconies are usually common property even though only one owner uses them, which makes the repair a body corporate matter. We quote in a format that works for a trustee meeting, with the scope and exclusions itemised.
Reading the damp below a balcony
Where the damp shows underneath tells you which detail has failed, before anything is lifted.
- A line along the slab edge or on the wall just under it points to a missing drip edge — water is wrapping back under the slab rather than falling clear.
- A patch below the door threshold points to the threshold junction, the most common entry point on any balcony.
- A stain in the middle of the ceiling below means water is passing through the field of the balcony: no membrane under the tiles, or a rigid one that has cracked.
- Damp that gets worse after long rain but not after a shower of it points to ponding — falls running the wrong way or a blocked outlet holding water on the slab.
Where the pattern is not conclusive, a formal leak trace with staged water testing isolates the detail. It is the one chargeable callout, and we say so before coming out.
What a balcony quote should name
- Whether the existing tile bed is stripped, and what that costs on its own line
- The screed correction, and which way the finished fall runs
- The membrane type — polyurethane, not a rigid coating — and where it is reinforced
- The upstand at every abutment and at the door threshold
- The outlet or scupper detail, and the drip edge
- The finish: tile on a drainage mat, or a trafficable top-coat
A quote that names the product and the m² rate but none of these details is pricing the easy part. The current rates are on the waterproofing prices page.
Related services
- waterproofing systems
- shower waterproofing
- wall crack repair and façade sealing
- waterproofing prices
- choosing a waterproofing contractor
- a free inspection
- contact us
Common questions
How much does balcony waterproofing cost?
About R450–R800 per m² including membrane, screed correction and a tile or trafficable finish. Stripping an existing failed tile bed is additional.
Can you waterproof a balcony without lifting the tiles?
Yes, but only with a surface-applied trafficable coating over the existing tiles, which works when the tiles are sound and well bonded and raises the finished level. Where the bed underneath is already saturated it is a delaying tactic.
Who pays for balcony waterproofing in a sectional title scheme?
In most South African schemes the balcony slab and its waterproofing are common property and therefore the body corporate's responsibility, even where the balcony is for the exclusive use of one section. Check your scheme's rules and conduct rules — exclusive-use provisions vary.